Appropriate anaesthesia technology for improved access to surgical services in resource constrained facilities in Northern Nigeria: A pilot study of the Universal Anaesthesia Machine


1 Department of Anaesthesiology and Intensive Care, Bayero University/Aminu Kano Teaching Hospital, Kano, Nigeria
2 World Health Organization, Regional Office for the Eastern Mediterranean, Cairo, Egypt
3 Department of Population and Family Health, Columbia University, New York, USA
4 Department of Obstetrics and Gynaecology, Bayero University/Aminu Kano Teaching Hospital, Kano, Nigeria

Correspondence Address:
Alhassan D Mohammed
Department of Anaesthesiology and Intensive Care, Bayero University/Aminu Kano Teaching Hospital, P.M.B. 3452, Kano
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2278-9596.202367

Rights and Permissions

Background: The provision of safe anesthesia in developing countries is often challenging due to multiple health systems and infrastructural challenges. We explored the suitability and reliability of the Universal Anaesthesia Machine (UAM) in Northern Nigeria. Patients and Methods: Over an 18-month period from 1st June 2012 to 30th November 2013, Nurse anesthetists and biomedical technicians were trained on the use, maintenance, and installation of the UAM in the study facilities. Patients requiring general anesthesia (GA) were then randomly assigned to the UAM or other forms of GA. Availability, ease of ues ans safety were monitored. Results: A total of 1562 patients had anesthesia administered with 54.8% using UAM. Cesarean section due to obstructed labor was the most common indication. There was no malfunctioning of the UAM and its use was preferred over other forms of GA. Complications were less than with other form of GA provided by the same staff. Conclusion: The UAM is suitable for health facilities with limited equipment and manpower. It has the potential to improve access to surgery and emergency obstetric care as it can be safely used by non-physician anesthetists.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6739    
    Printed327    
    Emailed0    
    PDF Downloaded400    
    Comments [Add]    

Recommend this journal